15x15 CO Sensor 1000 ppm Package 110-109 - 3SP_CO_1000 C

• Measurement Range: 0 to 1,000 ppm
• Resolution: < 100 ppb (instrumentation dependent)
• Repeatability: < ± 2 % of reading
• Small Size with Low Profile (20x20x3.8 mm)
• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Robust (passes 5000 ppm overload)
• Low Power (0 mW @ 0 mV bias)
• ROHS Compliant

  • Model Number: 3SP_CO_1000 C
  • Data Sheet: Date Sheet File
Quantity:
- +
  • 15x15 CO Sensor 1000 ppm Package 110-109
Mouse over image to zoom

Product Specification

3SP_CO_1000 C
15x15 CO Sensor 1000 ppm Package 110-109

BENEFITS
• Small Size with Low Profile (20x20x3.8 mm)
• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Robust (passes 5000 ppm overload)
• Low Power (0 mW @ 0 mV bias)
• Individually Calibrated (NIST Traceable)
• ROHS Compliant

APPLICATIONS
• Residential and Commercial CO Monitoring
• Industrial CO Monitors
• Ventilation Control
• RV and Marine CO Monitoring
• Indoor Air Quality
• Outdoor Air Quality

DESCRIPTION
SPEC Sensors’ Screen Printed ElectroChemical sensor technology (SPEC Sensor™) revolutionizes the current state of the art, enabling new applications in consumer and industrial safety monitoring. SPEC’s printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC’s printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size.

SPECIFICATIONS

Measurement Range

 0 to 1,000 ppm

Detection Limit

 0.5 ppm

Resolution

 < 100 ppb (instrumentation dependent)

Repeatability

 < ± 2 % of reading

Response Time - T(90)

 < 30 seconds (15 seconds typical)

Sensitivity

 4.75 ± 2.75 nA/ppm

Overload

 Passes EN20291-1 Sec. 5.3.6 5,000 ppm overload

Expected Operating Life

 > 5 years (10 years @ 23 ± 3 °C; 40 ± 10% RH)

Operating Temperature Range

 -30 to 55 °C (-20 to 40 °C continuous recommended)

Operating Humidity Range- non-condensing

 15 to 95% recommended continuous

 0 to >95% RH - intermittent

Operating Bias

 0 to 5 mV

Power Consumption

 10 to 50 uW (circuit & ambient CO dependent)


CROSS SENSITIVITY
Most chemical sensors exhibit some cross-sensitivity to other gases. The following table lists the relative response of common potential interfering gases, and the concentration at which the data was gathered.

Gas/Vapor

 Concentration

 Typical Response PPM CO

Carbon Dioxide

 5,000 ppm

 < 1

Hydrogen

 100 ppm

 17

Methane

 3,000 ppm

 < 1

Ammonia

 100 ppm

 < 1

Nitrogen Dioxide

 10 ppm

 < 1

Hydrogen Sulfide

 25 ppm

 < 1

Carbon Monoxide

 400 ppm

 400

Ozone

 5 ppm

 < 1

Sulfur Dioxide

 20 ppm

 < 1

Chlorine

 10 ppm

 < 1

n-Heptane

 500 ppm

 < 1

Toluene

 200 ppm

 < 1

Isopropyl Alcohol

 200 ppm

 1.3

Acetone

 200 ppm

 < 1


If you cannot find what you want, you can entrust ISweek to source for you. Just click: