15x15 Nitrogen Dioxide Sensor 0-5ppm P Package 110-507 - 3SP_NO2_5F P

• Measurement Range: 0 to 5 ppm
• Resolution: < 20 ppb (instrumentation dependent)
• Repeatability: < +/- 5 % of reading or 10ppb
• Response Time: < 15 seconds
• Operating Temperature: -40 to 50°C
• Operating Humidity: 0 to >95%RH non-condensing
• Power Consumption: 10 to 50 uW
• Long Life (10 years expected life)

  • Model Number: 3SP_NO2_5F P
  • Data Sheet: Date Sheet File
Quantity:
- +
  • 15x15 Nitrogen Dioxide Sensor 0-5ppm P Package 110-507
  • 15x15 Nitrogen Dioxide Sensor 0-5ppm P Package 110-507
Mouse over image to zoom

Product Specification

3SP_NO2_5F P
15x15 Filtered 0-5 ppm NO2 Sensor in Pinned Package 110-507

3SP_NO2_5F P Nitrogen Dioxide Sensor NO2 Sensor Description

SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size.


3SP_NO2_5F P 
Nitrogen Dioxide Sensor NO2 Sensor Benefits

• NEW Onboard Filter Removes Ozone!!!
• Improved stability and low ppm sensitivity
• Small Size with Low Profile (20 x 20 x 3 mm)

• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Low Power Consumption
• ROHS Compliant

 

3SP_NO2_5F P Nitrogen Dioxide Sensor NO2 Sensor Applications
• Air Quality Monitoring
• Industrial Safety
• Air Purification Control


3SP_NO2_5F P 
Nitrogen Dioxide Sensor NO2 Sensor 
Specifications

Measurement Range

0 to 5 ppm

Lower Detection Limit
< 20 ppb (instrumentation dependent)

Resolution

< 20 ppb (instrumentation dependent)

Repeatability

< +/- 5 % of reading or 10ppb

Response Time

< 15 seconds

Sensitivity @ -25 mV bias

-30 +/- 10 nA/ppm

Expected Operating Life

> 5 years (@ 23+/-3C; 40+/-10% RH)

Operating Temperature Range

-40 to 50°C (-20 to 40°C recommended)

Operating Humidity Range - non-condensing

0 to >95%RH (15 to 95% continuous)

Power Consumption

10 to 50 uW (circuit & ambient NO2 dependent)


3SP_NO2_5F P Nitrogen Dioxide Sensor NO2 Sensor Cross Sensitivity

Gas

ppm

Typical Response as ppm NO2

Carbon Monoxide

100

<0.02

Chlorine

10

<0.5

Ethanol

100

<1

Hydrogen Sulfide

5

<0.02

Nitric Oxide (NO)
5
<0.1

Nitrogen Dioxide

5

5

Ozone

1

<0.1

Sulfur Dioxide 

5

<0.02


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service