High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100% - SprintIR

• High speed sensing (20Hz)
• Measurement ranges from 0 to 100%
• Accuracy: ±70 ppm +/- 5% of reading
• Non Linearity: < 1% of FS
• 3.3V supply
• Low power requirement 35mW
• Flow through adaptor (Optional)
• Operating Pressure Range: 950 mbar to 10 bar

  • Model Number: SprintIR
  • Data Sheet: Date Sheet File
Quantity:
- +
  • High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
  • High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
  • High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
Mouse over image to zoom

Product Specification

High Speed Carbon Dioxide Sensor NDIR CO2 Sensor SprintIR Summary
SprintIR is a high speed (20 Hz) CO2 sensor, ideally suited for applications which require capture of rapidly changing CO2 concentrations including metabolic assessment and analytical instrumentation.

Fast, Accurate Carbon Dioxide Sensor
The SprintIR carbon dioxide sensor is the fastest, most accurate CO2 sensor on the market. A breakthrough in NDIR technology, the SprintIR uses advanced solid state Indium Antimonide LED’s and detectors to offer a robust sensor with no moving parts, no heated filaments, and incredibly low power requirements. The sensor comes in four versions - from 0% to 100% - all capable of the same high-speed CO2 measurement. This makes the SprintIR especially useful in biological applications.

    • High speed sensing (20Hz)
    • Measurement ranges from 0 to 100%
    • 3.3V supply
    • Low power requirement 35mW
    • Flow through adaptor (Optional)


High Speed Carbon Dioxide Sensor NDIR CO2 Sensor SprintIR Specifications

CO2 Measurement

Sensing Method

Non-dispersive infrared (NDIR) absorption

Patented Gold-plated optics

Patented Solid-state source and detector

Sample Method

Diffusion(Standard) / Flow through (with flow-through adapter)

Measurement Range

0-5%, 0-20%, 0-60%, 0-100%

Accuracy

±70 ppm +/- 5% of reading

Measurement Noise

<10% of reading with no digital filtering

Non Linearity

< 1% of FS

Pressure Dependence

0.1% of reading per mbar in normal atmospheric conditions

Operating Pressure Range

950 mbar to 10 bar

General Performance

Warm-up Time

< 1 minute

Operating Conditions

0°C to 50°C (Standard)

-25°C to 55°C (Extended range)

0 to 95%, RH non-condensing

Recommended Storage

-30°C to +70°C

Electrical/ Mechanical

Power Input

3.2 to 5V. (3.3V recommended)

Peak current 100mA

Average Current <15mA

Power Consumption

35 mW

Output

UART only 


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service