Hydrogen Chloride Sensor (HCL Sensor) - HCL-B1

• Range: 100ppm HCl limit of performance warranty
• Sensitivity: 150 to 250 nA/ppm in 25ppm HCl
• Response time t90: < 200 (s) from zero to 25ppm HCl
• Resolution: < 0.1 RMS noise (ppm equivalent)
• Temperature range: -30 to +50°C
• Pressure range: 80 to 120 kPa
• Humidity range: 15 to 90 % rh continuous
• Weight: < 13 g

  • Model Number: HCL-B1
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Hydrogen Chloride Sensor (HCL Sensor)
  • Hydrogen Chloride Sensor (HCL Sensor)
  • Hydrogen Chloride Sensor (HCL Sensor)
Mouse over image to zoom

Product Specification

HCL-B1 Hydrogen Chloride Sensor HCL Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.

Hydrogen Chloride (HCl)/Hydrogen Bromide (HBr)
The HCL sensor also detects Hydrogen Bromide (HBr). These HCL sensors are zero biased for easier use.
Available in A and B series.

HCL-B1 Hydrogen Chloride Sensor HCL Sensor PERFORMANCE
Sensitivity
nA/ppm in 25ppm HCl
150 to 250
Response time
t90 (s) from zero to 25ppm HCl
< 200
Zero current
ppm equivalent in zero air
0 to 3
Resolution
RMS noise (ppm equivalent)
< 0.1
Range
ppm HCl limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero, 40ppm HCl
0 to 6
Overgas limit
maximum ppm for stable response to gas pulse
200



HCL-B1 Hydrogen Chloride Sensor HCL Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/year in lab air, monthly test
nd
Operating life
months until 80% original signal (12 month warranted)
nd



HCL-B1 Hydrogen Chloride Sensor HCL Sensor ENVIRONMENTAL
Sensitivity @ 0°C
% (output @ 0°C/output @ 20°C) @ 25ppm HCl
80 to 95
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 25ppm HCl
100 to 108
Zero @ -20°C
ppm equivalent change from 20°C
< +0 to -1.0
Zero @ 50°C
ppm equivalent change from 20°C
< +0.5 to +2.5



HCL-B1 Hydrogen Chloride Sensor HCL Sensor CROSS SENSITIVITY
H2S   sensitivity
% measured gas @ ppm H2S
< 280
NO2   sensitivity
% measured gas @ ppm NO2
< -150
Cl2     sensitivity
% measured gas @ ppm Cl2
< -100
NO     sensitivity
% measured gas @ ppm NO
< 2
SO2   sensitivity
% measured gas @ ppm SO2 (transient peak)
< 1
CO     sensitivity
% measured gas @ ppm CO
< 0.1
H2     sensitivity
% measured gas @ ppm H2
< 0.1
C2H4 sensitivity
% measured gas @ ppm C2H4
< 0.1
NH3   sensitivity
% measured gas @ ppm NH3
< 0.1
CO2   sensitivity
% measured gas @ 5% CO2
< 0.1



HCL-B1 Hydrogen Chloride Sensor HCL Sensor KEY SPECIFICATIONS
Temperature range
°C
-30 to +50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in original container)
6
Load resistor
Ω (recommended)
10 to 33
Bias voltage
mV
not required
Weight
g
< 13

Matched Transmitter board for HCL-B1 HCL Sensor

4-20mA Analogue Transmitter Board
  • Factory calibration, custom-set for immediate use
  • Wide operating voltage range
  • Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.


4-20mA Digital Transmitter Board
   • Factory calibration, custom-set for immediate use
   • Digital zero, sensitivity and temperature compensation
   • Digital and 4-20mA output
   • Biased or unbiased operation
   • Calibration and range change

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service