Low Cost Submersion and In-Line pH Electrodes - S222/S260/S270 Series

• Measuring Range: 0-14 pH (Sodium ion error >12.3pH)
• Economical design for in-line or submersion use
• Choose from single or double junction models
• Threaded 1/2" or 3/4" NPT connections
• Choose from spherical or flat pH measuring surfaces
• Special models for low ionic and other specialty applications available

  • Model Number: S222/S260/S270 Series
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Low Cost Submersion and In-Line pH Electrodes
  • Low Cost Submersion and In-Line pH Electrodes
  • Low Cost Submersion and In-Line pH Electrodes
Mouse over image to zoom

Product Specification

Low Cost Submersion and In-Line pH Electrodes


Item No.:

S200C, S200CD&S200CD-LC, S222C, S222CD, S223C, S223CD, S224C, S224CD, S265C/CD, S267C/CD, S268CD, S269CD, S271CD, S272CD&S272CDTC, S273CD&S273CDTC, S353CD, S354CD


Low Cost Submersion and In-Line pH Electrodes Features
• Economical design for in-line or submersion use
• Choose from single or double junction models
• Threaded 1/2" or 3/4" NPT connections
• Choose from spherical or flat pH measuring surfaces
• Special models for low ionic and other specialty applications available 

Low Cost Submersion and In-Line pH Electrodes Description
This series of electrodes is designed to provide an economical multi-purpose solution for in-line or submersion pH measurements. Based on our proven S200C bulb and S350CD flat surface pH glass technology, these rugged and durable electrodes are available in Ryton nipples with 1/2" or 3/4" NPT threads; or in our durable epoxy body with or without quick disconnect top caps. Choose from single or double junction designs, flat or recessed measuring surface configurations and cable lengths and connectors as required. For special configurations such as low ionic models, fluoride resistant pH glass and other specialty sensors, please contact the Sensorex sales or technical support department.


Low Cost Submersion and In-Line pH Electrodes Specifications

Measuring Range
0-14 pH (Sodium ion error >12.3pH)
Body material

Epoxy (S200,S222, S353, S354 Series) or Ryton (S265-S269 Series, 
S271CD, S272CD & S273CD

Max Temp/Pressure
S265-S269 Series : 32-176 deg F ( 0-80 deg C))/70 psig
S271CD,S272CD & S273CD : 170 deg F (75 de C))/100 psig, 
180 deg F (81 deg C)/85 psig, 212 deg F (100 deg C)/50 psi

Connector 

BNC, tinned wires (other connectors available for an addi tional charge), 
S353CD AND S353CD have DIN Cap and require DIN-EL mating connecto

Cable length

30" or longer for S200 Series lengths at additional cost user specified 
(Cap-cable S653 required for S222 Series). 10ft length for S265-S269 series, 
10ft waterproof cable for S271CD, S272CD & S273C

Process Connection
1/2" or 3/4" MNPT for submersion or in-line, S354CD has DIN 13.5mm threads


Low Cost Submersion and In-Line pH Electrodes Ordering Information
These economical sensors are submersion and in-line ready by utilizing the 1/2" or 3/4” MNPT threads on the sensor. 10ft cable length is standard. Special lengths available upon request. 

pH Sensors  
Body Material  
Key Features
(To order an ORP model instead of pH, simply add - ORP to the model numbers below.)
S265C
PPS
Single junction 1/2" NPT spherical bulb
S265CD
PPS
Double junction 1/2" NPT spherical bulb
S267C
PPS
Single junction 3/4" NPT spherical bulb
S267CD
PPS
Double junction 3/4" NPT spherical bulb
S268CD
PPS
Double junction 1/2" NPT flat surface
S269CD
PPS
Double junction 3/4" NPT flat surface
S271CD
PPS
Double junction 3/4" NPT spherical bulb, heavy duty
S272CD
PPS
Double junction 3/4" NPT flat surface , heavy duty
S272CDTC
PPS
Double junction 3/4" NPT flat surface , heavy duty with Temperature Sensor, 
Pt100 or Pt1000RTD

S273CD
PPS
Double junction 3/4" NPT hemi pH glass surface , heavy duty
S273CDTC
PPS
Double junction 3/4" NPT hemi pH glass surface , heavy duty with Temperature Sensor, 
Pt100 or Pt1000RTD


Low Cost Submersion and In-Line pH Electrodes Ordering Information
These economical sensors can be used for submersion or in-line use. Mounting is accomplished by ordering the appropriate mounting gland listed below.
Sensor
Type
S200C
Single junction spherical style bulb
S200CD
Double junction spherical style bulb
S200CD-LC
Low ionic, double junction, spherical style bulb
S222C
Single junction spherical style bulb-Quick disconnect
S222CD
Double junction spherical style bulb-Quick disconnect
970796
Double junction flat pH glass-Quick disconnect
S223C
Single junction spherical style bulb- DIN Cap
S223CD
Double junction spherical style bulb-DIN Cap
S353CD
Double junction flat pH glass-DIN Cap

DIN 13.5 Threaded Cap Sensors - (Do not require mounting fitting. Mount via DIN 13.5 thread)
Sensor
Type
S224C
Single junction spherical style bulb- DIN 13.5 Cap(S6)
S224CD
Double junction spherical style bulb-DIN 13.5 Cap(S6)
S354CD
Double junction flat pH glass-DIN 13.5 Cap(S6)

Accessories
FC50P
1/2 " NPT mounting gland for 12mm electrodes
FC75P
3/4 " NPT mounting gland for 12mm electrodes
FC75TC
3/4 "flow cell, mounting gland and ATC cable for 12mm electrodes
S653
Cap Cable assembly for S222 series (Specify cable length and 
connector termination when ordering)

EXT Cable - DIN EL/"X"
Extension cable for DIN cap and DIN 13.5 electrodes (Series S223, S224, S354)
TX100
4-20mA loop-powered pH transmitter
B104
1 pint 4.01 pH Buffer
B107
1 Pint 7.00 pH Buffer
B110
1 Pint 10.00 pH Buffer


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service