LuminOx Fluorescence Optical Oxygen Sensor (O2 Sensor) - LOX-02

• Supply Voltage: 4.5 to 5.5 Vdc
• Output Type: 3.3V TTL level RS232
• Operating Temperature: -30°C to +60°C
• Humidity: 0-99% Rh (non-condensing)
• Oxygen Measuring Range: 0-25% O2
• Oxygen Pressure Range: 0-300mbar ppO2
• Response Time T90: <30s (Typical)
• ppO2 Accuracy / Resolution: <2%FS / 0.1mbar

  • Model Number: LOX-02
  • Data Sheet: Date Sheet File
Quantity:
- +
  • LuminOx Fluorescence Optical Oxygen Sensor (O2 Sensor)
  • LuminOx Fluorescence Optical Oxygen Sensor (O2 Sensor)
Mouse over image to zoom

Product Specification

LOX-02 LuminOx Fluorescence Optical Oxygen Sensor (O2 Sensor) Description
The low cost, low power and long life are what differentiates the LuminOx gaseous optical oxygen sensor from other oxygen sensors.

Developed and manufactured by SST, the LuminOx family is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of fluorescence quenching by oxygen.

The patented technology allows SST to produce a sensor that provides low power operation, while offering a much longer lifetime than electrochemical and galvanic sensors.

The LuminOx oxygen sensor is internally temperature compensated meaning the customer does not need to consider this in their design. It also communicates directly to the customer’s UART so no signal conditioning circuitry is required.

LuminOx is a completely solid state sensor and contains no lead or liquid electrolytes. It is therefore 100% RoHS compliant. It also has virtually no cross sensitivity, allowing it to be used in applications where other technologies are unreliable due to the particular mix of gases present.

LuminOx measures the partial pressure of oxygen (ppO2) which, along with the internal sensor temperature is communicated serially to the host microcontroller. LuminOx is also available with an internal barometric pressure sensor. This enables oxygen concentration (%O2) to be calculated and transmitted, along with the ppO2, temperature and barometric pressure.


LOX-02 Optical Oxygen Sensor (O2 Sensor) Benefits
• Low power
• Can also measure O2 % & barometric pressure
• Suitable for battery power use
• Long life
• High accuracy
• Small & compact
• Low cost
• Maintenance free
• Contains no hazardous materials
• Connects directly to microcontroller without any additional circuitry.
• Factory Calibrated

LOX-02 Optical Oxygen Sensor (O2 Sensor) Applications
• Oxygen Detection
• Portable Equipment
• Breathing Apparatus
• Inerting
• Medical
• Lab Equipment
• Agriculture
• Incubation
• Fire Prevention
• Flue Gas in Condensing Boilers

LOX-02 Optical Oxygen Sensor Electrical and Environmental Specification

Supply Voltage (Vs)
4.5 to 5.5 Vdc
Supply Current (Is)
<7.5mA (streaming 1 sample per second), <20mA Peak
Output Type
3.3V TTL level RS232
Operating Temperature
-30°C to +60°C
Storage Temperature
-30°C to +60°C
Humidity
0-99% Rh (non-condensing)
Barometric Pressure Range
500 to 1200 mbar

LOX-02 Optical Oxygen Sensor (O2 Sensor) Performance Specification*
Oxygen Measuring Range
0-25% O2
Oxygen Pressure Range 0-300mbar ppO2
Response Time
T90 <30s (Typical)
ppO2 Accuracy / Resolution
<2%FS / 0.1mbar
Temperature Accuracy / Resolution
Indication Only / 0.1°
Pressure Accuracy / Resolution
±5mbar / 1mbar
O2 % Accuracy / Resolution
Determined by ppO2 and Pressure Accuracy / 0.1%
Lifetime
>5 years
*At ambient conditions. All performance measurements are at STP unless otherwise stated. Following extreme temperature fluctuations, re-calibration may be required.

Matched Transmitter board for LOX-02 LuminOx Fluorescence Optical Oxygen Sensor

LOX-EVB LuminOx Optical Oxygen Sensor Evaluation Interface Board
The LuminOx Sensor family is a range of factory calibrated oxygen sensors which measure ambient ppO₂ levels using the principle of fluorescence quenching by oxygen.
The LuminOx Evaluation interface Board has been designed to allow customers to quickly and easily evaluate the sensor with the minimum of effort or design work
The LuminOx Evaluation Kit simultaneously provides three outputs:
• RS232 (serial interface voltage levels)
• RS485 (Modbus RTU) port allows multiple sensors to be addressed on a bus
• 0-5V Analogue output for basic measurements of oxygen only

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service