Photoionization Gas Sensor - PID-AH

Target gases: < 10.6 eV VOCs with ionisation potentials
Minimum detection level: 1 ppb isobutylene
Linear range: 50 ppm isobutylene 3% deviation
Overrange: 50 ppm isobutylene
Sensitivity: > 20 linear range mV / ppm Isobutylene
Full stabilisation time: 20 minutes to 20 ppb
Warm up time: 5 seconds time to full operation
Offset voltage: 46 to 60 mV variable between detectors
Response time (t90): < 3 seconds diffusion mode

  • Model Number: PID-AH
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Photoionization Gas Sensor
Mouse over image to zoom

Product Specification

1. PID-AH Photoionization Gas Sensor Schematic Diagram


2. PID-AH Photoionization Gas Sensor notes

1. Do not obstruct Ø3.5 sensing area
2. Seal between Ø6.2 and Ø9.0 (if different to atmosphere)
3. Pin out details:
    Pin 1: + V supply (See note 5)
    Pin 2: Signal output
    Pin 3: 0V supply
4. All dimensions ±0.1mm unless otherwise stated
5. Input voltage selector hole:
    a) When filled with solder the onboard regulator is disabled. A regulated supply of 3.0 - 3.6V (typically 3.3V) is then required.
    b) When not filled with solder the onboard regulator is enabled. A regulated or unregulated supply between 3.6 - 10 V is then required for IS applications, or up to 18 V for non-IS applications.
Nomally shipped with regulator enabled


3. PID-AH Photoionization Gas Sensor PERFORMANCE

Target gases   VOCs with ionisation potentials   < 10.6 eV
Minimum detection level   ppb isobutylene   1
Linear range   ppm isobutylene                      3% deviation   50
Overrange   ppm isobutylene   50
Sensitivity   linear range                               mV / ppm Isobutylene   > 20
Full stabilisation time   minutes to 20 ppb   20
Warm up time   seconds                                     time to full operation   5
Offset voltage   mV variable between detectors   46 to 60
Response time (t90 )   seconds                                      diffusion mode   < 3

4. PID-AH Photoionization Gas Sensor ELECTRICAL
Power consumption   85 mW (max) at 3.2 V, 300 mW transient for 200 msec on switch-on
Supply voltage 

 3.2 to 3.6 VDC Ideally regulated ±0.01V (onboard regulator disabled)

 3.2 to 10 VDC (onboard regulator enabled)
 (maximum 10V for IS approval, maximum 18 V for non-IS)

Output signal 

 Offset voltage (minimum 46 mV) to Vmax

 (Vmax = Vsupply -0.1 V when regulator is enabled)


5. PID-AH Photoionization Gas Sensor ENVIRONMENTAL
Temperature range  -40℃ to +55℃ (Intrinsically Safe); -40℃ to +65℃ (non-IS)
Temperature dependence   0℃ to 40℃ 90% to 100% of signal at 20℃
 -20℃ 140% of signal at 20℃
Relative humidity range   Non-condensing 0 to 95%
Humidity sensitivity   During operations: 0% to 75% rh transient near zero

6. PID-AH Photoionization Gas Sensor KEY SPECIFICATIONS
Operating life   5 years (excluding replaceable lamp and electrode stack)
IS Approval   IECEx Ex ia IIC T4; ATEX Ex ia II 1G -40℃ < Ta < +55℃ (< 10VDC supply)
Onboard filter   To remove liquids and particulates
Lamp   User replaceable
Electrode stack   User replaceable
Error state signal   Lamp out: 35 mV
Weight   < 8g
Position sensitivity   None
Warranty period 

 Electronics and housing: 24 months

 Lamp and electrode stack are user replaceable. 10.6eV lamp: 5,000 lit hours