Tin Dioxide Semiconductor Gas Sensor for Ammonia Detection - SP-53A-00

• Target gas: Ammonia
• Heater voltage: 5.0 V ± 4%
• Circuit voltage: 5.0 V ± 4%
• Operating temperature: -10°C to 60°C
• Storage temperature: -20°C to 70°C
• Relative humidity: Less than 95% RH
• Sensor resistance: 9kΩ to 90 kΩ
• Industrial gas leak detector

  • Model Number: SP-53A-00
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Tin Dioxide Semiconductor Gas Sensor for Ammonia Detection
  • Tin Dioxide Semiconductor Gas Sensor for Ammonia Detection
Mouse over image to zoom

Product Specification

SP-53A-00 Ammonia Sensor NH3 Sensor Description
The SP-53A is a tin dioxide semiconductor gas sensor which has a good sensitivity to high concentration ranges of ammonia with improved response speed compared with conventional models.

SP-53A-00 Ammonia Sensor NH3 Sensor Application
• Industrial gas leak detector

SP-53A-00 Ammonia Sensor NH3 Sensor Specifications

Standard Operating conditions
Symbol
Parameter
Specification
Conditions etc.
VH
Heater voltage
5.0 V ± 4 %
AC or DC
VC Circuit voltage
5.0 V ± 4 %
AC or DC
RL Load resistance
Variable
PS < 15 mW
RH Heater resistance
42 Ω ± 2 Ω
at room temperature
PH Heater power consumption
380 mW (Typical value)
PH = VH2 / RH
PS
Power dissipation of
sensing element
Less than 15 mW
PS =(VC - VRL)2/RS
Environmental conditions
Symbol
Parameter
Specification
Conditions etc.
Tao
Operating temperature
-10°C to 60°C
Recommended range
Tas
Storage temperature
-20°C to 70°C
RH
Relative humidity
Less than 95% RH
(O2)
Oxygen concentration
21% ± 1%
(Standard condition)

Absolute minimum level:
more than 18%
The sensitivity characteristics are influenced by the
variation in oxygen concentration.

Sensitivity characteristics
Model
SP-53A-00
Symbol
Parameter
Specification
Conditions etc.
RS
Sensor resistance
9kΩ to 90 kΩ
At 600 ppm of ammonia/air
β
Ratio of sensor resistance
0.15 to 0.35
Rs at 600 ppm of ammonia
Rs at 200 ppm of ammonia

Standard Test Conditions:
Temp: 20°C ± 2°C
Humidity:65% ± 5%
(in clean air)
VC : 5.0 V ± 1%  
VH : 5.0 V ± 1%  
RL : 10 kΩ ± 5%
Pre-heating time: more than 48 hours
Mechanical characteristics
Items
Conditions
Specifications
Vibration
Frequency:
Vertical amplitude:
Duration:
100 cpm
4 mm
1 hour
Should satisfy the
specifications shown in the
sensitivity characteristics.

Shock
Acceleration:
Number of impacts:
100 G
5 times

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service