15x15 Nitrogen Dioxide Sensor 20 ppm P Package 110-501 - 3SP_NO2_20 P

• Measurement Range: 0 to 20 ppm
• Resolution: < 20 ppb (instrumentation dependent)
• Repeatability: < +/- 3 % of reading
• Response Time T90: < 300 ( 200 seconds typical)
• Operating Temperature: -40 to 50°C
• Operating Humidity: 0 to 100%RH non-condensing
• Power Consumption: 10 to 50 uW

  • Model Number: 3SP_NO2_20 P
  • Data Sheet: Date Sheet File
Quantity:
- +
  • 15x15 Nitrogen Dioxide Sensor 20 ppm P Package 110-501
  • 15x15 Nitrogen Dioxide Sensor 20 ppm P Package 110-501
Mouse over image to zoom

Product Specification

3SP_NO2_20 P
15x15 NO2 Sensor 20 ppm P Package 110-501

3SP_NO2_20 P Nitrogen Dioxide Sensor NO2 Sensor Description

SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size.


3SP_NO2_20 P 
Nitrogen Dioxide Sensor NO2 Sensor Benefits

• Small Size with Low Profile (20x20x3 mm)
• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Low Power Consumption
• Individually Calibrated (NIST Traceable)
• ROHS Compliant

 

3SP_NO2_20 P Nitrogen Dioxide Sensor NO2 Sensor Applications
• Air Quality Monitoring
• Industrial Safety
• Air Purification Control


3SP_NO2_20 P 
Nitrogen Dioxide Sensor NO2 Sensor 
Specifications

Measurement Range

 0 to 20 ppm

Resolution

 < 20 ppb (instrumentation dependent)

Repeatability

 < +/- 3 % of reading

Response Time T90

 < 300 ( 200 seconds typical)

Sensitivity @ -200 mV bias

 -40 +/- 15 nA/ppm

Expected Operating Life

 > 5 years (10 years @ 23+/-3C; 40+/-10% RH)

Operating Temperature Range

-40 to 50°C (-20 to 40°C recommended)

Operating Humidity Range - non-condensing

 0 to 100% RH (15 to 95% recommended)

Power Consumption

 10 to 50 uW (circuit & ambient NO2 dependent)


3SP_NO2_20 P Nitrogen Dioxide Sensor NO2 Sensor Cross Sensitivity

Gas/Vapor

Concentration

Typical Response PPM NO2

Methane

500 ppm

< 0.1

Ammonia

100 ppm

< 0.1

Nitrogen Dioxide

10 ppm

10

Hydrogen Sulfide

25 ppm

-5.8

Carbon Monoxide

400 ppm

< 0.1

Ozone

5 ppm

5

Sulfur Dioxide

20 ppm

< 0.1

Nitric Oxide (NO)

50 ppm

0.2

Chlorine

10 ppm

< 0.1

n-Heptane

500 ppm

< 0.1


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service