1kg to 50kg Load Cell - TCA

1kg to 50kg Load Cell TCA
Nominal Load from 1kg to 50kg
Linearity: 0.03%
Output: 2mV/V
Protection: IP67

  • Model Number: TCA
  • Data Sheet: Date Sheet File
Quantity:
- +
  • 1kg to 50kg Load Cell
  • 1kg to 50kg Load Cell
  • 1kg to 50kg Load Cell
Mouse over image to zoom

Product Specification

TCA

1kg to 50kg Load Cell


ALUMINIUM strain gages Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION


Dimensions   [mm]


Technical Data

NOMINAL LOAD
1(1) - 2(1) - 5(1) kg(2)
10 - 25 - 50 kg(2)
NOMINAL SENSITIVITY
SENSITIVITY TOLERANCE
2 mV/V
≤ ± 0.1%
TEMPERATURE EFFECT (10 °C)
a) on zero
b) on sensitivity

≤ ± 0.025 %
≤ ± 0.021 %

LINEARITY
HYSTERESIS
REPEATABILITY
≤ ± 0.03 %
≤ ± 0.03 %
≤ ± 0.01 %
INPUT RESISTANCE
OUTPUT RESISTANCE
INSULATION RESISTANCE
ZERO BALANCE
RECOMMENDED SUPPLY VOLTAGE
NOMINAL SUPPLY VOLTAGE
MAXIMUM SUPPLY VOLTAGE
440 ± 20 Ω
350 ± 2 Ω
>5 GΩ
≤ ± 1 %
10 V
1-15 V
18 V
MECHANICAL LIMIT VALUES
REFERRED TO NOMINAL LOAD:
a) service load
b) max permissible load
c) breaking load
d) max transverse load
e) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD

120 %

150 %
>300 %
50 %
50 %
∼ 0.3 mm

REFERENCE TEMPERATURE
TEMPERATURE NOMINAL RANGE
SERVICE TEMPERATURE
STORAGE TEMPERATURE
+23 °C
-10 / +40 °C
-20 / +70 °C
-20 / +80 °C
WEIGHT
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL
CABLE LENGTH
∼ 0.3 kg
IP20
Alluminio / Aluminium
3 m
RECOMMENDED KNUCKLE JOINTS
DURBAL EM6
  (1) Supplied with overload protection TENSION and COMPRESSION (Max. 500% F.S.).
  (2) N calibrations on request


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service