BLV Series Low Voltage Pressure Sensors - BLV-L10D-B1NS-N​

• 0 to 30 inH2O Pressure Ranges
• Supply Voltage (Vs) 6 Vdc
• Common Mode Pressure 5 psig
• Lead Temperature (soldering 2-4 sec.) 270 °C
• Operating Temperature: -25 to 85 °C
• Storage Temperature: -40 to 125 °C
• Humidity Limits: 0 to 95% RH (non condensing)

  • Model Number: BLV-L10D-B1NS-N​
  • Data Sheet: Date Sheet File
Quantity:
- +
  • BLV Series Low Voltage Pressure Sensors
  • BLV Series Low Voltage Pressure Sensors
  • BLV Series Low Voltage Pressure Sensors
Mouse over image to zoom

Product Specification

BLV Series Low Voltage Pressure Sensors General Description
The BLV Series Basic Sensor is based on All Sensors' CoBeam Technology. The device provides a high output signal at a low operating voltage and reduces the overall supply voltage while maintaining comparable output levels to traditional equivalent basic sensing elements. This lower supply voltage gives rise to improved warm-up shift while the CoBeam Technology itself reduces package stress susceptibility resulting in improved overall long term stability. The technology also vastly improves position sensitivity compared to conventional single die devices.

This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output is also ratiometric to the suply voltage and is operable from 0.9 to 1.8 volts DC.

BLV Series Low Voltage Pressure Sensors Features
• 0 to 1 "H2O to 0 to 30 "H2O Pressure Ranges
• uPower Low Supply Voltage (0.9V to 1.8V)
• 90% Less Power Than Mini-Basic Series
• 0.3% Linearity
• Improved Front to Back Linearity
• Excellent Position Sensitivity
• Improved Warm-Up Shift Distribution
• Parylene Coating Available Upon Request

BLV Series Low Voltage Pressure Sensors Applications
• Medical Instrumentation
• Environmental Controls
• HVAC
• Portable / Hand Held Devices

BLV Series Low Voltage Pressure Sensors

Pressure Sensor Maximum Ratings

Environmental Specifi cations
Supply Voltage
6 Vdc
Operating Temperature
-25 to 85 °C
Common Mode Pressure
5 psig
Storage Temperature
-40 to 125 °C
Lead Temperature (soldering 2-4 sec.)
270 °C
Humidity Limits
0 to 95% RH (non condensing)

BLV Series Low Voltage Pressure Sensors Standard Pressure Ranges
Device
Operating Range
Proof Pressure
Burst Pressure
BLV-L01D
±1 inH2O
100 inH2O
300 inH2O
BLV-L05D
±5 inH2O
200 inH2O
300 inH2O
BLV-L10D
±10 inH2O
200 inH2O
300 inH2O
BLV-L20D
±20 inH2O
200 inH2O
500 inH2O
BLV-L30D
±30 inH2O
200 inH2O
800 inH2O

Performance Characteristics for BLV Series Low Voltage Pressure Sensors
All parameters are measured at 1.8 volt excitation and room temperature unless otherwise specified . Pressure measurements are with positive pressure applied to port B (the only port for the single port configuration ).
Parameter
Min
Typ
Max
Units
Notes
Output Span





    L01D @ 1 inH2O
4.5
8.0
11.5
mV 
4
    L05D @ 5 inH2O
13.5
24.0
34.5
mV 
4
    L10D @ 10 inH2O
18.0
32.0
46.0
mV 
4
    L20D @ 20 inH2O
22.0
38.0
55.0
mV 
4
    L30D @ 30 inH2O
25.0
42.0
60.0
mV 
4
Offset Voltage @ Zero Diff. Pressure
- - ±10
mV
-
Offset Temperature Shift (0°C-70°C)
- -25.0
- uV/°C
1
Offset Warm-up Shift
- -20.0
±100
uV
2
Offset Position Sensitivity (1g)
- ±20.0
- uV
-
Offset Long Term Drift (One Year)
- ±120
- uV
-
Linearity, Hysteresis Error
- 0.10
±0.30
%FSS
3
Response Time (10% to 90% Pressure Response)
- 100
- uS
-
Front to Back Linearity
- 0.25
- %FSS
5
Temperature Effect on Resistance (0°C-70°C)
- 2800
- ppm/°C
-
Temperature Effect on Span (0°C-70°C)
- -1900
- ppm/°C
-
Input Resistance
- 3.0
- k ohm
-
Output Resistance
- 3.0
- k ohm
-

BLV Series Low Voltage Pressure Sensors How To Order
Example: BLV-L10D-B1NS-N

If you cannot find what you want, you can entrust ISweek to source for you. Just click: