Carbon Dioxide (CO2) Gas Detector - F2000TSM-CO2-S/L

• Gas detected: Carbon Dioxide (CO2)
• CO2 measuring range:
0~2,000ppm / 0~5,000ppm selectable in orders
0~20,000ppm / 0~50,000ppm just for TSM-CO2-S series
• Response time: <2 minutes for 90% step change
• Sensor life: Up to 15 years
• Power supply: 24VAC/24VDC
• Operation temperature: 0~50°C(32~122°F)
​• Operation humidity​: 0~95%RH, non condensing

  • Model Number: F2000TSM-CO2-S/L
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Carbon Dioxide (CO2) Gas Detector
  • Carbon Dioxide (CO2) Gas Detector
  • Carbon Dioxide (CO2) Gas Detector
Mouse over image to zoom

Product Specification

Carbon Dioxide Detector
Model: F2000TSM-CO2 Series
CE Approval


F2000TSM-CO2 Series Carbon Dioxide Detector Features
• Real-time detecting CO2 level.
• NDIR infrared CO2 module inside with four CO2 detection range selectable.
• CO2 sensor has Self-Calibration Algorithm and 15 years lifetime
• Wall-mounting
• Providing one analog output with voltage or current selectable
• 0~10VDC/4~20mA selectable easily via jumpers
• Special "L" series with 6 lights indicates CO2 level and makes CO2 level show clearly.
• Provide a special model with a on/off relay output with a touch button to operate a fan control.
• Design for HVAC, ventilation systems, offices, or other public places.
•  Modbus RS485 communication interface optional: 15KV antistatic protection, independent address setting
• CE-Approval
• For duct probe CO2 transmitter, and CO2+ Temp.+ RH 3 in 1 transmitter, please see our other products.


F2000TSM-CO2 Series Carbon Dioxide Detector Specifications

Gas detected
Carbon Dioxide (CO2)
Sensing element
Non-Dispersive Infrared Detector (NDIR)
Accuracy@25℃(77℉),2000ppm
±40ppm + 3% of reading or ±75ppm (whichever is greater)
Stability
<2% of FS over life of sensor (15 yr typical)
Calibration interval
ABC Logic Self Calibration System
Response time
<2 minutes for 90% step change
Warm up time
2 hours (first time)
2 minutes (operation)
CO2 measuring range
0~2,000ppm / 0~5,000ppm selectable in orders
0~20,000ppm / 0~50,000ppm just for TSM-CO2-S series
Sensor life
Up to 15 years
Power supply
24VAC/24VDC
Consumption
1.5 W max. ; 0.8 W avg.
Analog outputs
0~10VAC or 4~20mA selectable by jumpers
Relay output
1X2A switch load
Four set points selectable by jumpers
6 LED lights
(just for TSM-CO2-L series)
From left to right:
Green/Green/Yellow/Yellow/Red/Red
1st green light on as CO2 measurement ≤600ppm
1st and 2 nd green lights on as CO2 measurement >600ppm and ≤800ppm
1st yellow light on as CO2 measurement >800ppm and ≤1,200ppm
1st and 2nd  yellow lights on as CO2 measurement >1,200ppm and ≤1,400ppm
1st red light on as CO2 measurement >1,400ppm and ≤1,600ppm
1st and 2nd red lights on as CO2 measurement >1,600ppm
Modbus interface
Modbus RS485 interface
9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV
antistatic protection.
Operation conditions
0~50°C(32~122°F); 0~95%RH, non condensing
Storage conditions
0~50°C(32~122°F)
Net weight
180g
Dimensions
100mm x 80mm x 28mm
Installation standard
65mm x 65mm or 2" x 4" wire box
Approval
CE-Approval

F2000TSM-CO2 Series Carbon Dioxide Detector Models Guide

Type
Model
Description
CO2 Detector
(1xanalog,1Xon/off output)
F2000TSM-CO2-S100-V/A-02
1X analog output, CO2 range: 0~2,000ppm
F2000TSM-CO2-S100-V/A-05
1X analog output, CO2 range: 0~5,000ppm
F2000TSM-CO2-S100-V/A-20
1X analog output, CO2 range: 0~20,000ppm
F2000TSM-CO2-S100-V/A-50
1X analog output, CO2 range: 0~50,000ppm
F2000TSM-CO2-S110-V-02
1X0~10V output and 1xon/off output
CO2 range: 0~2000ppm
CO2 Detector
(1xanalog output, Modbus
RS485 interface)
F2000TSM-CO2-S101-V/A-02
1X analog output, Modbus RS485 communication.
F2000TSM-CO2-S101-V/A-05
1X analog output, Modbus RS485 communication
F2000TSM-CO2-S101-V/A-20
1X analog output, Modbus RS485 communication.
F2000TSM-CO2-S101-V/A-50
1X analog output, Modbus RS485 communication.
CO2 Detector
with 6 indicator lights
F2000TSM-CO2-L101-N-02/05
6 lights indicate CO2 measurements range,
Modbus interface
F2000TSM-CO2-L100–V/A-02/05
6 lights indicate CO2 measurements range,
1x analog output
F2000TSM-CO2-L101–V/A-02/05
6 lights indicate CO2 measurements range,
1x analog output, Modbus RS485 interface
F2000TSM-CO2-L110-V-02
CO2 transmitter and indication, 1x 0~10VDC output, 1X
on/off output with a touch button. CO2 range: 0~2000ppm
F2000TSM-CO2-L110-N-02
6 lights indicate CO2 measurements range,
1x relay output
F2000TSM-CO2-L111-N-02
6 lights indicate CO2 measurements range,
1x relay output, Modbus interface


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service