Cooling Tower Conductivity Sensor and Flow Cell - CS8000TC

• Range: k=1.0 +/-10%
• Max Temperature/Pressure: 60 deg C(140 deg F)/100 psig
• ​Quick disconnect design saves time and money
• ​Installs in seconds! No tools necessary
• ​Flat surface design resists coating
• ​Internal Temperature Sensor
• ​Great for cooling towers

  • Model Number: CS8000TC
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Cooling Tower Conductivity Sensor and Flow Cell
  • Cooling Tower Conductivity Sensor and Flow Cell
  • Cooling Tower Conductivity Sensor and Flow Cell
Mouse over image to zoom

Product Specification

CS8000TC Cooling Tower Conductivity Sensor and Flow Cell

Parts covered by this product data sheet include:
CS8000TC, FC875/S, FC875/T, S855

CS8000TC Cooling Tower Conductivity Sensor Features
• Quick disconnect design saves time and money
• Installs in seconds! No tools necessary
• Flat surface design resists coating
• Internal Temperature Sensor
• Great for cooling towers

CS8000TC Cooling Tower Conductivity Sensor Description
The new CS8000TC sensor is an easy-to-install conductivity sensor, ideally suited for cooling TDS monitoring. A keyed flange is used to align the sensor in the ideal orientation for trouble free monitoring. Sensor removal is simple with the detachable S855 cable assembly. There's no need to pull the cable through conduit -- just hand-loosen the knurled nut and remove the sensor.

Temperature compensation is included with a choice of sensor types, 10K NTC, 30K NTC, Pt1000 RTD & Pt100 RTD to match the requirements of your conductivity transmitter or controller.

Flush mount graphite measuring surface is easily cleaned with detergent and a soft bristled brush.


CS8000TC Cooling Tower Conductivity Sensor Specifications

Range
k=1.0 +/-10%
Wetted Materials
CPVC, Graphite, Viton®
Max Temperature/Pressure
60 deg C(140 deg F)/100 psig
Temperature Compensation
Choice of 10K or 30K NTC or Pt100 or Pt1000 RTD.


CS8000TC Cooling Tower Conductivity Sensor and Flow Cell OUTLINE & DIMENSIONS



CS8000TC Cooling Tower Conductivity Sensor and Flow Cell Ordering Information
Part Number
Description
CS8000TC
Cooling Tower Conductivity sensor, CPVC constructions, graphite measuring
surface, intergrated temperature sensor (specify). Requires flow cell and cable
FC875/S
Flow cell, CPVC construction for CS8000TC, 3/4" socket connection
FC875/T
Flow cell, CPVC construction for CS8000TC, 3/4" NPT threaded connection
S855/10/TL/TL
Cable assembly for CS800TC, 10ft Length, tinned wires
S855/20/TL/TL
Cable assembly for CS800TC, 20ft Length, tinned wires


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service