UV Sensor Probe - GUVx-T1xGC-3LO1

- Single Supply Voltage
- Analog Voltage Output
- High Temperature Environment (under 200°C)
- Supply Voltage: 9 - 24VDC
- Supply Current: 3.3mA
- Detection Range:
GUVV-T11GC-3LO1: 230 - 395nm
GUVB-T12GC-3LO1: 220 - 320nm
GUVC-T11GC-3LO1: 220 - 280nm

  • Model Number: GUVx-T1xGC-3LO1
  • Data Sheet: Date Sheet File
Quantity:
- +
  • UV Sensor Probe
  • UV Sensor Probe
Mouse over image to zoom

Product Specification

GUVx-T1xGC-3LO1 UV Sensor Probe Feature
- Single Supply Voltage
- Analog Voltage Output
- High Temperature Environment (under 200°C)


GUVx-T1xGC-3LO1 UV Sensor Probe Application
- UV Power Measure
- UV Lamp Monitoring

GUVx-T1xGC-3LO1 UV Sensor Probe Case dimensions

LO Probe (mm)
LO Probe Material
Optical Fiber
Diameter
 Total
Length (m)
Core (mm)
Material
20 56 Al-60
1 1 SUS 304

GUVx-T1xGC-3LO1 UV Sensor Probe Absolute Maximum Ratings

Absolute Maximum Ratings
Min.
Typ.
Max.
Unit
Remark
Operating Temperature
Optical Fiber


200 °C

LO Probe
-30
85 °C


GUVx-T1xGC-3LO1 UV Sensor Probe Electro-Optical Characteristics (at 25°C)

Parameter
Symbol
Min.
Typ.
Max.
Unit
Remark
Supply Voltage
Vcc
9
24 VDC
Supply Current
IQ

3.3
mA
Detection Range
GUVV-T11GC-3LO1
λ
230
395 nm 10% of Max
GUVB-T12GC-3LO1
λ
220
320 nm
GUVC-T11GC-3LO1
λ
220
280 nm
Output Voltage
Vout
0
5 V
Detection Power Range
P 0
100 mW/cm2
Response Time
T
10
ms


If you cannot find what you want, you can entrust ISweek to source for you. Just click: