Industrial Grade Solar Sensor - ML-01

• Response time 95%: < 1 ms
• Non-stability (change/year): ± 2 %
• Non-linearity (at 1000W/m²): < 0.2 %
• Directional response error (0 - 80º): < 10 W/m²
• Sensitivity50​µV/W/m²
• Impedance: 50​Ω
• Operating temperature range: -30 to +70​°C

  • Model Number: ML-01
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Industrial Grade Solar Sensor
  • Industrial Grade Solar Sensor
Mouse over image to zoom

Product Specification

ML-01 Si-Pyranometer


ML-01 Industrial Grade Solar Sensor Description
The ML-01 Si-sensor is the link between the reference cell and broadband thermopile pyranometer. Compared to the reference sensors it has a proper cosine repose and it is relatively compact, but benefits from the same characteristics as a PV module (Response time, Spectral and temperature response).

The ML-01 is an industrial grade solar sensor specially made for Performance ratio measurements as well as irradiance measurement applications for the meteorological, agricultural and environmental studies. The compact dimensions of the sensor body make it easy to integrate within any application using it with or without the mounting plate. For global horizontal measurement applications the sensor can be mounted in horizontal position with the standard removable mounting plate with spirit level and leveling feet.

ML-01 Industrial Grade Solar Sensor Features
• Fast Response Time (10ms)
• CIE Photopic Response
• Glass Dome Plus Dissufor Optics
• Low Temperature Dependency

ML-01 Industrial Grade Solar Sensor Specifications
Specifications (Typical)
ML-01
ISO 9060 classification
N/A
Response time 95%
< 1 ms
Zero offset - Thermal radiation (200W/m²)
0 W/m²
Zero offset - Temperature change (5K/hr)
0 W/m²
Non-stability (change/year)
± 2 %
Non-linearity (at 1000W/m²)
< 0.2 %
Directional response error (0 - 80º)
< 10 W/m²
Spectral selectivity (0.35-1.5µm)
Si-Photo diode response
Temp. response (for 50°C band)
< 0.15 %/°C
Tilt response (at 1000W/m²)
0 %
Sensitivity (µV/W/m²)
50
Impedance (Ω)
50
Operating temperature range (°C)
-30 to +70
Cable length
5 m
Wavelength range (nm)
400 - 1100 (Mono-Crystalline)
Mounting Plate
Standard

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service