Optical Dissolved Oxygen Sensor - RDO BLUE

• POND AQUACULTURE
• RECIRCULATING AQUACULTURE SYSTEMS
• OPEN PEN AQUACULTURE
• SURFACE WATER SPOT SAMPLING
• REMOTE MONITORING VIA TELEMETRY

  • Model Number: RDO BLUE
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Optical Dissolved Oxygen Sensor
  • Optical Dissolved Oxygen Sensor
  • Optical Dissolved Oxygen Sensor
Mouse over image to zoom

Product Specification

RDO® Blue Optical Dissolved Oxygen Sensor Description:

    RDO Blue uses In-Situs patented Optical Rugged Dissolved Oxygen technology, an EPA-approved dissolved oxygen measurement method ideal for measuring DO and temperature in even the harshest environments. Suitable for handheld use or long-term deployment in fresh water or saltwater, this low-maintenance dissolved oxygen probe offers robust performance at a lower cost than other DO meters.

    RDO Blue requires no calibration or conditioning prior to deployment and doesnt use membranes. The replaceable RDO Smart Sensor Cap stores calibration coefficients for automatic, error-free setup. And a unique, three-layer system provides unmatched chemical and abrasion resistance.

    Use included Modbus/RS485 communication protocol to easily integrate with PLC systems or telemetry with HydroVu data services for real-time feedback and process control.

 

RDO® Blue Optical Dissolved Oxygen Sensor Applications:

POND AQUACULTURE

RECIRCULATING AQUACULTURE SYSTEMS

OPEN PEN AQUACULTURE

SURFACE WATER SPOT SAMPLING

REMOTE MONITORING VIA TELEMETRY

 

RDO® Blue Optical Dissolved Oxygen Sensor Technical parameters:

SENSOR RATINGS

SENSOR TYPE

Optical Dissolved Oxygen Sensor

RANGE, DO

0-60 mg/L; 0-600% Saturation

ACCURACY, DO

+/- 0.1 mg/L (0-20 mg/L)

+/-2% (20-60 mg/L)

RESOLUTION, DO

0.01 mg/L

RESPONSE TIME, CAP

T63<5s, T90<45s, T95<60s (RDO-X cap)

UNITS, DO

mg/L, ppm, % saturation

RANGE, TEMP.

-5to 50(23°F to 122°F)

ACCURACY, TEMP.

+/- 0.1

RESOLUTION, TEMP.

0.01

UNITS, TEMP.

Celsius, Fahrenheit

SALINITY COMP.

Fixed or real-time capable

BAROMETRIC COMP.

Fixed or real-time capable

METHODS

EPA-approved In-Situ® RDO methods 1002-8-2009,

1003-8-2009, 1004-8-2009 Standard Methods 4500-O

ENVIRONMENTAL RATINGS

PRESSURE

150 psi from 0° to 50

DEPTH

100m (328ft) @ 25

OPERATING TEMP.

(NON-FREEZING)

-5.0to + 50.0℃(23°F to 122°F

STORAGE TEMP.

-40to + 65℃(-40°F to 149°F

COMPLIANCE

EMC 2014/30/EU

IEC 61000-6-2:2005

EN 55011:2009

IP RATING

IP-67 with sensor cap off; IP-68 with sensor cap installed

CHEMICAL RATINGS

INTERFERENCES

Alcohols >5%; hydrogen peroxide > 3%; sodium hypochlorite (commercial bleach) > 3%; gaseous sulfur dioxide; gaseous chlorine. Do not use in organic solvents (e.g., acetone, chloroform, methylene chloride, etc.), which may swell the sensing element (foil matrix)

and destroy it.

GENERAL RATINGS

DIMENSIONS

L 22.06 cm (8.69 in) x D 2.95 cm (1.16 in)

WEIGHT

205 g (0.5 lb) (without cable)

WETTED MATERIALS

Ryton®(PPS), Cycoloy® (PC/ABS), PC/PMMA, TPU

COMMUNICATION OUTPUT

Modbus/RS485

READING RATE

1 reading every 1 second

POWER REQUIREMENTS

8 to 36 VDC

POWER CONSUMPTION

Maximum (measurement): 50 mA at 12 VDC

Idle (communication only): 2 mA at 12 VDC

WARRANTY

2 years from date of shipment

NOTES: Ryton is a registered trademark of Solvay SA.; Cycoloy is a registered trademark of SABIC GLOBAL Technologies B.V.


If you cannot find what you want, you can entrust ISweek to source for you. Just click: