Probe Humidity and Temperature Transmitter - CAEL-S16

• Metal probe reduce electromagnetic interference
• Interchangeable sensor for rapid maintenance
• 0 - 100%RH measurement,
• Probe pressure up to 10 bar
• Calculated hygrometric outputs
• Two channel with selectable physical quantity
• Unit support metric or imperial

  • Model Number: CAEL-S16
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Probe Humidity and Temperature Transmitter
  • Probe Humidity and Temperature Transmitter
Mouse over image to zoom

Product Specification

CAEL-S16 Humidity and Temperature Transmitter Features
• Metal probe reduce electromagnetic interference
• Interchangeable sensor for rapid maintenance
• 0 - 100%RH measurement,
• Probe pressure up to 10 bar
• Calculated hygrometric outputs
• Two channel with selectable physical quantity
• Unit support metric or imperial

CAEL-S16 Humidity and Temperature Transmitter Applications
• Semiconductor and microelectronics industry
• Food production and packaging
• Agriculture, farms
• Environmental chambers, drying equipment, spraying equipment
• Greenhouse, storage room, cooling chamber
• HVAC

CAEL-S16 Humidity and Temperature Transmitter Technical Data

Humidity
Measurement range 
0 - 100 %RH
Accuracy (including non-linearity, hysteresis, and repeatability)
  CAEL-S16A
1.5%RH@25℃ (20 - 80%RH)
±2%RH@25℃ (0 - 20/80 - 100%RH)
  CAEL-S16
2%RH@25℃ (20 - 80%RH)
±3%RH@25℃ (0 - 20/80 - 100%RH)
  CAEL-S16B
3%RH@25℃ (20 - 80%RH)
Temperature coefficient (from 0°C to 80°C)
typ. ±0.02%RH/℃
Humidity Hysteresis
±1%RH
Recovery time after 150 hours of condensation
10 second
Long term drift
< 0.25%RH/year
Response Time (at 63% of signal) from 33 to 75%RH
5 second (at 1m/s air flow)


Temperature
Measurement range
-40 ~ 105℃
Accuracy (including non-linearity, hysteresis, and repeatability)
±0.7℃ (-40 ~ 5℃)
±0.3℃ (5 ~ 60℃)
±0.9℃ (60 ~ 105℃)
Long term drift
< 0.02℃/year


Analog output (two channels)
Voltage version   
0 - 1 V / 5 V / 10 V
Accuracy of analog outputs at +25 °C 
±0.1% full scale
Temperature dependence 
±0.005%/°C full scale
External loads
current output RL < 500 ohm
voltage output 0 - 1 V output RL > 2k ohm
0 - 5 V and 0 - 10 V outputs RL > 10k ohm


RS485 output with Modbus RTU
ID
1 - 247
Baud rate
9600/ 19200/38400/57600/115200
Data format
N81/N82/E81/E82/O81/O82


Psychrometric calculations (option)
(Td) dew point temperature, (Tf) frost/dew point temperature, (R) mixing ratio,
(A) absolute humidity, (S) enthalpy, (Tw) wet bulb temperature, (E) water vapor pressure 


Power supply
Analog output 0-1V
5 - 28VDC
Analog output 0-5V / 10V 
15 - 28VDC
RS485 output
12 - 28VDC


Power consume (25 °C, V+ 24 VDC)
Analog output
typ. 3mA
RS485 output
typ. 3mA


Mechanics
Probe material
brass nickel-plated
Probe pressure
10bar
Housing classification
IP65
Cable
M12 4-pin 2M female


Operation Temperature range
-40 ~ 105°C (-40 ~ 221°F)


Electromagnetic compatibility
EN61326-1:2013 Emission
CISPR11:2009+A1:2010 Group 1 Class B
EN61326-1:2013 Immunity
IEC 61000-4-2:2008
IEC 61000-4-3:2006+A1:2007+A2:2010
IEC 61000-4-8:2009

CAEL-S16 Humidity and Temperature Transmitter Ordering Guide
Model
Output
Temperature Scale
Psychrometric calculations
(Option)

CAEL-S16A
CAEL-S16
CAEL-S16B 

0 - 10V      (3)
0 - 5V        (5)
0 - 1V        (6)
RS485       (4)
0 - 50°C         (1)
0 - 100°C       (2)
By order        (S)
none              (X)
Yes           (M)
No



Ordering example
CAEL-S16-31M
Humidity accuracy: ±2%RH (20 - 80%RH)
Output: 0 - 10V
Temperature Scale: 0 ~ 50°C
Option - Psychrometric calculations: Yes 

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service