    The MFC2000 series mass flow controllers utilize the company's proprietary MEMS Thermal D Operation heat sensing technology with intelligent control electronics. This unique mass flow sensing technology eliminates the gas sensitivity of some gases with similar diffusivity and allows gas identification after programming. This product can be used for process control with a dynamic range of 100:1, with a pressure range of 0.1 to 1MPa(15 to 150 PSI) and a compensation temperature of 0 to 50C. The product is designed for easy replacement of mechanical connectors, standard connectors are NPT1/8 "to 1/2", and other custom connectors are available on request.

     For non-corrosive gas flow control applications, full size mass flow from 50sccm to 200slpm with analog set point or RS485 Modbus interface for mass flow control.



Characteristics and application

• Mass flow, time domain sensing technology

• The range ratio is 100:1

• can measure a wide range of gases without special correction

• Mechanical interfaces can be customized

• A variety of standard communication options are available

• The sensor surface is passivated with a silicon nitride ceramic material and a water/oil resistant nano coating to improve performance and reliability. The technology also provides better linearity and increased temperature

It can be mainly used in various mass flow control applications, such as chemical reaction units, medical equipment, environmental monitoring, energy and other fields.


Technical specifications 

All specifications listed in the following table unless otherwise noted apply for calibration conditions at 0 °C and 101.325 kPa absolute pressure with air. The product is horizontally mounted at the time of calibration.

 

Value

Unit

Full-scale range

Full-scale range

0 ~ 50 sccm…0 ~ 1000 sccm

0 ~ 2 … 0 ~ 200 SLPM

 

Accuracy

± 1.5% r.d. (20 ~ 100% of full scale)

±0.3% f.s. (<20% of full scale)

 

Repeatability

± 0.5% r.d. (20 ~ 100% of full scale)

±0.1% f.s. (<20% of full scale)

 

Turn-down ratio

100:1

 

Max control range

120

%FS

Control pressure range

0.1 ~ 0.8

MPa

Maximum operating differential pressure

0.4

MPa

Setpoint voltage

0 ~ 5.0

Vdc

Settling time

100

msec

Working temperature

0 ~ 55

°C

Humidity

<95, no condensation

%RH

Burst pressure

1.5

MPa

Max pressure loss

80 (100 SLPM models)

kPa

Power supply

8 ~ 24

Vdc

Analog output

0 ~ 5.0

Vdc

Max null shift (analog)

±30

mVdc

Control valve

Normally Closed (NC)

 

Digital output*

RS485 Modbus

 

Electrical connector

DB9

 

Mechanical connection

1/8”… 1/2” FNPT

 

Protection

IP40

 

Storage temperature

-20 ~ 70

 

Reference conditions

0 °C, 101.325 kPa, air

 

CE

EN61000-2; -3; -4

 

Environmental

RoHS, REACH

 


Mechanical dimensions 

Different ranges correspond to different sizes



Product selection

The product part number is composed of the product model number and suffixes indicating the fullscale flow rate, as well as the other parameters. Refer to the following for details.