15x15 H2S Sensor 50 ppm Package 110-304 - 3SP_H2S_50 C

• Measurement Range: 0 to 50 ppm
• Resolution: < 5 ppb (instrumentation dependent)
• Repeatability: < +/- 3 % of reading
• Small Size with Low Profile (20x20 x3.0mm)
• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Low Power Consumption
• ROHS Compliant

  • Model Number: 3SP_H2S_50 C
  • Data Sheet: Date Sheet File
Quantity:
- +
  • 15x15 H2S Sensor 50 ppm Package 110-304
  • 15x15 H2S Sensor 50 ppm Package 110-304
Mouse over image to zoom

Product Specification

3SP_H2S_50 C
15x15 H2S Sensor 50 ppm Package 110-304

3SP_H2S_50 C Hydrogen Sulfide Sensor H2S Sensor Description
SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost andll size.


3SP_H2S_50 C Hydrogen Sulfide Sensor H2S Sensor Benefits
• Small Size with Low Profile (20x20 x3.0mm)
• Long Life (10 years expected life)
• Fast Response (< 15 seconds)
• Low Power Consumption
• Individually Calibrated (NIST Traceable)
• ROHS Compliant


3SP_H2S_50 C Hydrogen Sulfide Sensor H2S Sensor Applications
• Fixed Industrial Safety Monitoring
• Portable Industrial Safety Detection
• Portable Personal Safety Monitor
• Indoor Air Quality Monitoring
• Outdoor Air Quality Monitoring
• Bad Breath/Halitosis Respiration Sensing


3SP_H2S_50 C Hydrogen Sulfide Sensor H2S Sensor Specifications

Measurement Range

 0 to 50 ppm

Resolution

 < 5 ppb (instrumentation dependent)

Repeatability

 < +/- 3 % of reading

Response Time

 < 15 seconds typical

Sensitivity @ 0 mV bias

 212 +/- 87 nA/ppm

Expected Operating Life

 > 5 years (10 years @ 23+/-3C; 40+/-10% RH)

Operating Temperature Range

 -30 to 55 C (-20 to 40 C recommended)

Operating Humidity Range - non-condensing

 0 to 100% RH (15 to 95% recommended)

Power Consumption

 10 to 50 uW (circuit & ambient H2S dependent)


3SP_H2S_50 C Hydrogen Sulfide Sensor H2S Sensor Cross Sensitivity

Gas/Vapor

Concentration

Typical Response PPM H2S

Methane

500 ppm

0.1

Ammonia

100 ppm

0.1

Nitrogen Dioxide

10 ppm

-2.0

Hydrogen Sulfide

25 ppm

25

Carbon Monoxide

400 ppm

1.1

Ozone

5 ppm

-0.9

Sulfur Dioxide

20 ppm

1.7

Nitric Oxide (NO)

50 ppm

1.2

Chlorine

10 ppm

-2.2

n-Heptane

500 ppm

< 0.05


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service