Electrochemical VOC sensor - VOC-B4

4-Electrode Volatile Organic Compound Sensor

  • Model Number: VOC-B4
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Electrochemical VOC sensor
Mouse over image to zoom

Product Specification

VOC-B4 Electrochemical VOC sensor Schematic Diagram

 


VOC-B4 Electrochemical VOC sensor SPECIFICATION CO SENSING

PERFORMANCE

Sensitivity

nA/ppm in 2ppm CO

400 to 700

Response time

t90 (s) from zero to 2ppm CO

< 30

Zero current

nA in zero air at 20

± 200

Noise*

±2 standard deviations (ppb equivalent)

20

Range

ppm limit of performance warranty

100

Linearity

ppm CO error at full scale, linear at zero, 10ppm CO

± 1

Overgas limit

maximum ppm for stable response to gas pulse

1000

LIFETIME

Zero drift

ppb equivalent change/year in lab air

±500

Sensitivity drift

% change/year in lab air, monthly test

< 15

Operating life

months until 50% original signal (24 month warranted)

> 36

ENVIRONMENTAL

Sensitivity @ -20(% output @ -20°C/output @ 20) @ 2ppm CO

60 to 80

Sensitivity @ 50(% output @ 50°C/output @ 20) @ 2ppm CO

90 to 110

Zero @ -20

nA change from 20

± 20

Zero @ 50

nA change from 20

1800 to 2200

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service