High-temperature Gage Pressure Transmitters 0-40MPa - MIDA-SG-12-081-C

Standard ranges 0-40MPa
Operating temperature range:
-40 ... +300 - for A-zone;
40…+80 - for electronics ambient temperature (C-zone)
Overall accuracy in compensated temperature range no more than: ±0,5​%
Supply voltage: 12 ... 36V depending on loads resistance
Ingress protection: IP64
Consumed current, no more, 20,2mA

  • Model Number: MIDA-SG-12-081-C
Quantity:
- +
  • High-temperature Gage Pressure Transmitters 0-40MPa
Mouse over image to zoom

Product Specification

High-temperature Gage Pressure Transmitters 0-40MPa MIDA-SG-12-081-C

SG-12-081-C is based on Russia advanced titanium / silicon - sapphire dry flat membrane pressure sensor and advanced analog circuit. It is with wide pressure range, wide temperature range, high stability, wear resistance, impact resistance and anti-corrosion and other prominent features.

Also, it is easy cleaning and can be used for Industrial instrumentation & process control systems for high temperature media


High-temperature Gage Pressure Transmitters Specification

Applications Industrial instrumentation & process control systems for high temperature media, including viscous liquids, polymer melts
Measured medium High-temperature liquids, gases, melts compatible with titanium alloys and stainless steel
Standard ranges, MPa 0-0,4… - 0-40
Output signal (wires) 4-20 mA (2-wire)
Operating temperature range,℃

-40 ... +300 - for A-zone;

 40…+80 - for electronics ambient temperature (C-zone)

Compensated temperature range of output signal,℃
+20 ...+300
Overall accuracy in compensated temperature range, no more than ±%
0,5
Supply voltage, V 12 ... 36 depending on loads resistance
Consumed current, no more, mA 20,2
Type and marking of intrinsic safety
0ExiaIICT2
Ingress protection IP64
Climatic modification UHL**3.1
Mechanical stability V3
Electrical connection Sealing gland straight (S) and angle (A); plug/socket (P)
Pressure port 
Pressure port, thread specified on drawing
Weight no more than, kg 0,6
Specifications ТУ4212-043-18004487-2003
Number in the State Register of measuring devices of the Russian Federation
17635 - 03


High-temperature Gage Pressure Transmitters Overall and mounting dimensions

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service