• Measuring range of particles: 0.3~1.0; 1.0~2.5; 2.5~10 μm
• Effective range of particle mass concentration: 0~500 μg/m3
• Maximum range of particle mass concentration: 999 μg/m3
• Resolution: 1 μg/m3
• Single measurement response time: 1s
• Total response time: ≤10s
• DC power supply voltage: 5.0 V
• Working current: ≤100 mA

  • Model Number: DL0001
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Laser Dust Sensor
  • Laser Dust Sensor
Mouse over image to zoom

Product Specification

DL0001 Laser Dust Sensor Introduction
The Laser Dust Sensor is used to measure the concentration of suspended particles in the air with different sizes (including PM2.5). It uses a laser diode as the light source to illuminate the sampling air boosted by the blower. When the small particles in the air enter the illuminated area, the laser beam is scattered. The scattered light is received by a photodetector and converted into current signal which is amplified and processed then to indicate the concentration of particles. A built-in microprocessor converts it into mass concentration (μg/m3) and outputs the signal via universal digital interface.

DL0001 Laser Dust Sensor Features
• Lensless design to ensure good consistency
• High accuracy measurement
• Can detect particles as small as 0.3μm in diameter

DL0001 Laser Dust Sensor Applications
• Ventilation system
• Air purifier
• Air quality monitor
• Automotive air purification
• Air conditioner
• Other home appliances

DL0001 Laser Dust Sensor Technical Parameters

Measuring range of particles
0.3~1.0; 1.0~2.5; 2.5~10 μm
Effective range of particle mass concentration
0~500 μg/m3
Maximum range of particle mass concentration
999 μg/m3
Resolution
1 μg/m3
Consistency (PM2.5 standard value)
± 10 % @ 100 ~ 500 μg/m3
± 10 μg/m 3 @ 0 ~ 100 μg/m3
Single measurement response time
1s
Total response time
≤10s
DC power supply voltage
5.0 V
Working current
≤100 mA
Data interface level
<0.8 @3.3 V     H >2.7@3.3 V
Working temperature range
-10 ~ +50 ℃
Working humidity range
35~85%
Storage temperature range
-40 ~ +80 ℃
Mean time to failure
≥3 years
Maximum size
50 x 40 x 25mm

If you cannot find what you want, you can entrust ISweek to source for you. Just click: