Zirconia Oxygen Sensor System - O2S-FR-T2-18BM-C-RS485

• Oxygen range (Modbus RTU)​: 0.1-100% O2​
• Long life, non-depleting technology
• Integral heating element
• High accuracy
• Linear output signal
• No reference gas required
• No need for temperature stabilisation
• Probe mounting positions available; 28mm
• M18x1.5 screw mounting

  • Model Number: O2S-FR-T2-18BM-C-RS485
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Zirconia Oxygen Sensor System
  • Zirconia Oxygen Sensor System
Mouse over image to zoom

Product Specification

O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System Description
The Zirconia Oxygen Sensor System offers a complete solution, removing the need for customers to develop their own electronics. Frequently used in combustion control systems, burning coal, oil, gas and biomass and in oxygen generation systems.

The Zirconia Oxygen Sensor System consists of SST’s fast response (<4s T90) zirconium dioxide (ZrO₂) screw fit sensor in conjunction with the OXY-LC oxygen sensor interface board.


O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System FEATURES
• Fast response zirconium dioxide (ZrO2) sensor in conjunction with the OXY-LC oxygen sensor interface board
• Long life, non-depleting technology 
• Integral heating element
• High accuracy
• Linear output signal

O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System BENEFITS
• No reference gas required
• No need for temperature stabilisation
• Probe mounting positions available; 28mm
• M18x1.5 screw mounting

O2S-FR-T2-18BM-C-RS485 Zirconia Oxygen Sensor System TECHNICAL SPECIFICATIONS

Supply voltage 
    RS485 output variant:
8-28V DC
Supply current
600mA max. at 24V DC
1.2A max. at 12V DC
Digital output
RS485 (Modbus RTU)
Pump impedance at 700°C
< 6kΩ
Permissible gas temperature
-100°C to +250°C
Gas flow rate
0-10m/s
Operating pressure limits
260-1260mbar absolute
Mounting thread
M18 x 1.5

O2S-FR-T2-18BM-C-RS485 Zirconia O2 Sensor System OUTPUT VALUES

Oxygen range (Modbus RTU)
0.1-100% O2
Accuracy after calibration
0.5% O2
Output resolution
0.01% O2
Response time (10-90% step)
< 4s
Initial warm up time (till stable output)
5 - 10mins
Output inactive start up delay (heater warm up)
    From Standby to ON mode (RS485 only):

20s


O2S-FR-T2-18BM-C-RS485 Zirconia O2 Sensor System ORDER INFORMATION
Referring to the tables below will allow you to tailor a system to suit your specific requirements.

Interface Board

PCB Part Number
O2 Measure Range
Output Type
Heater Voltage
OXY-LC-485
0.1% and 100%
Modbus RTU
Configurable

Sensor

Sensor Part Number Probe Length
O2S-FR-T2-18BM-C
28mm

If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service