Electromagnetic Flowmeter - FEM06

Flow Velocity range : 0...12 m/s
Be applicable sewage, wastewater, chemical plants, food factory application IP68 enclosure that can be used for underground applications
FEP Liner suitable in vacuum tube High accuracy of ±0.5% of reading Empty pipe, current excitation

  • Model Number: FEM06
  • Data Sheet: Date Sheet File
Quantity:
- +
  • Electromagnetic Flowmeter
Mouse over image to zoom

Product Specification

FEM06 Electromagnetic Flowmeter Introduction:

FEM06 Electromagnetic Flowmeter is a flange type electromagnatic flowmeter ideal for conductive liquids. It comes in sizes from 15 to 800mm flow tubes.

Electromagnetic Flowmeter is widely used for tap-water, waste water, food & beverage pulp & paper and many other applications.

Can be is a stand alone magmeter that could also be used with various configurations, such integral or remote and AC or DC power requirement. RS485 communications are available.


FEM06 Electromagnetic Flowmeter Feature :

Flow Velocity range : 0...12 m/s

Be applicable sewage, wastewater, chemical plants, food factory application IP68 enclosure that can be used for underground applications

FEP Liner suitable in vacuum tube High accuracy of ±0.5% of reading Empty pipe, current excitation


FEM06 Electromagnetic Flowmeter Application :

High viscous fluids 

Corrosive and abrasive liquids process industry

waste water treatment

chemical industry

steel industry

mining,pulp & paper

irrigation

power generation.



FEM06 Electromagnetic Flowmeter Specification:

Item

Function & Parameter

Diameter

15 ... 800 mm ( 1/2" to 32" )

Range

Velocity 0 ... 0.25m/s min. ; 0 ... 12m/s max

Material

Measuring Tube : Stainless Steel 304

Flange : Cabon Steel ( Standard ) ; Stainless Steel 304 ( Option )

Housing : Carbon Steel ( Standard ) ; Stainless Steel 304 ( Option )

Protection

IP67 for compact version ,and IP68 for remote version

Conductivity

To be more than 20 μS/cm

PowerSupply

110 ... 240VAC or 24 VDC

Output

4...20mA / Pulse ; 4...20mA / Pulse & RS-485

Liner

Rubber ( 50 ... 800 mm )

FEP ( 15 ... 250 mm ) ; FEP ( F46 ) (10 ... 250 mm ) ;


PTFE ( 15 ... 800 mm ) ; PFA ( 10 ... 400 mm )

Electrode

SUS316L ; Hastelloy ; Titanium ; Tantalum

Process Connection

Flange

Flange type

ANSI、DIN、JIS

Grounding Resistance

< 10 Ω

Ambient Temp

- 25 ... + 65 °C

Temperature

80℃ ( Rubber ) ; - 20 ... + 100 °C ( PTFE )

 - 40 ... + 150 °C ( FEP ) ( F46 ) ; - 20 ... + 120 °C (PFA )

Accuracy

( Velocity ≧ 0.3 ... 12 m/s )

± 0.5% of reading ( 15 ... 600 mm ) ; 0.25% option

1 % of reading ( 700 ... 800 mm )

Working Pressure

4.0Mpa. : Max Pressure with flanges ( 10 ...150mm )

2.5Mpa. : Max Pressure with flanges ( 200 ... 600mm )

1.6Mpa. : Max Pressure with flanges ( 700 ... 800mm )


If you cannot find what you want, you can entrust ISweek to source for you. Just click:

Sourcing Service