UV Sensor Probe - GUVx-T1xGC-3LW10

- Water Environment (<10 bar)
- Single Supply Voltage, 0-5V Voltage Output
- AlGaInN-based UV Sensor
- Supply Voltage: DC 9~24 V
- Supply Current:3.3mA
- Detection Range:
GUVV-T11GC-3LW10: 230~395nm
GUVB-T12GC-3LW10: 220~320nm
GUVC-T11GC-3LW10: 220~280nm

  • Model Number: GUVx-T1xGC-3LW10
  • Data Sheet: Date Sheet File
Quantity:
- +
  • UV Sensor Probe
  • UV Sensor Probe
Mouse over image to zoom

Product Specification

GUVx-T1xGC-3LW10 UV Sensor Probe Feature
- Water Environment (<10 bar)
- Single Supply Voltage, 0-5V Voltage Output

GUVx-T1xGC-3LW10 UV Sensor Probe Application
- UV Power Measure
- UV Lamp Monitoring

GUVx-T1xGC-3LW10 UV Sensor Probe Case dimensions

Thread/Length for Mounting
Diameter (mm)
 Window (mm)
Wrench Size (mm)
Length (mm)
Weight (g)
Body (stainless steel)
PT3/4 " /16 mm 30 7
26 62 200
316L (1.4404)

GUVx-T1xGC-3LW10 UV Sensor Probe Absolute Maximum Ratings
Parameter
Symbol
Min.
Typ.
Max.
Unit
Remark
Storage Temperature
Tst
-40
90 °C

 Operating Temperature
Top
-30
85 °C


GUVx-T1xGC-3LW10 UV Sensor Probe Electro-Optical Characteristics (at 25°C)

Parameter
Symbol
Min.
Typ.
Max.
Unit
Remark
Supply Voltage
Vcc
9
24 V DC
Supply Current
IQ

3.3
mA
Detection Range
GUVV-T11GC-3LW10
λ
230
395 nm 10% of Max
GUVB-T12GC-3LW10
λ
220
320 nm
10% of Max
GUVC-T11GC-3LW10
λ
220
280 nm
10% of Max
Output Voltage
Vout
0
5 V
Detection Power Range
P 0
100 mW/cm2
Response Time
T
10
ms
* Maximum of detection power : 20 mW/cm2 (Option), 100 mW/cm2 (Standard), 1000 mW/cm2 (Option)